Yaskawa VS-616G5 Series Revision F Programming Manual User Manual
Page 32

V/f
V/f w/PG Open Loop
Vector
Flux
Vector
32
VS-616G5 Programming Manual
If any of the parameters C1-01 to C1-09 is set to 600.1 seconds or more, C1-10 cannot be set to “0”.
Setting Range:
0.0 to 400.0Hz
Factory Default:
0.0Hz
Accel/decel times can be changed automatically, without using the multi-function contact inputs.
Use accel/decel times set in parameters C1-01 and C1-02 when output frequency
≥
C1-11.
Use accel/decel times set in parameters C1-07 and C1-08 when output frequency < C1-11.
When multi-function contact inputs are set for accel/decel selection, this command has priority over
automatic change of accel/decel.
C2
S-Curve Accel/Decel
An S-curve pattern is used to reduce shock and provide smooth transitions during machine accelera-
tion and deceleration. S-curve characteristic time is the time from the output frequency to the set accel/
decel time.
Setting Range:
0.00 to 2.50s
Factory Default:
0.20s
C1-10 Accel/Decel Time Setting Unit
Acc/Dec Units
A
A
A
A
Setting
Description
0
Accel/decel time (C1-01 to C1-09) setting range is in units of 0.01 second.
Accel/decel time setting range: 0.00 to 600.00s
1
Accel/decel time (C1-01 to C1-09) setting range is in units of 0.1 second.
Accel/decel time setting range: 0.0 to 6000.0s (factory default)
C1-11 Accel/Decel Time Switching Frequency Level
Acc/Dec SW Freq
A
A
A
A
C2-01 S-Curve Time at Acceleration Start
SCrv Acc @ Start
A
A
A
A
C2-02 S-Curve Time at Acceleration End
SCrv Acc @ End
A
A
A
A
C2-03 S-Curve Time at Deceleration Start
SCrv Dec @ Start
A
A
A
A
C2-04 S-Curve Time at Deceleration End
SCrv Dec @ End
A
A
A
A
Output Frequency
C1-07
Accel/Decel Switching Level
C1-01
C1-02
C1-08
(C1-11)
Figure 14 Accel/Decel Switching Level Adjustment
Section C: Tuning Parameters
C2 S-Curve Accel/Decel