SMA WB 3000-21 Installation User Manual
Page 66

11 Troubleshooting
SMA Solar Technology AG
66
WB3-5TL-21-IA-en-10
Installation Manual
3701
Resid.curr.too high
The inverter has detected a residual current after brief
grounding of the small wind turbine system.
Corrective measures:
• Check the small wind turbine system for ground
3801 to
3802
DC overcurrent
Check generator
Overcurrent at the DC input. The inverter briefly interrupts
feed-in.
Corrective measures:
• If this message is frequently displayed, ensure that
the small wind turbine system is correctly rated and
correctly connected to the rectifier.
• Ensure that the DC inputs on the inverter are
bridged (see Section 6.4.3).
3901 to
3902
Waiting for DC start
conditions
Start cond. not met
The conditions for the feed-in to the power distribution
grid have not been met.
Corrective measures:
• Wait for stronger wind, if necessary reduce the
critical voltage to start feed-in. To do this, change
the parameter Critical voltage to start feed-in or
A.VStr.
• If this message is frequently displayed at medium
wind conditions, ensure that the small wind turbine
system is correctly rated.
6001 to
6009
Self diagnosis
Interference device
The cause must be determined by the SMA Service Line.
Corrective measures:
• Contact the SMA Service Line.
6101 to
6112
Self diagnosis
Interference device
The cause must be determined by the SMA Service Line.
Corrective measures:
• Contact the SMA Service Line.
6202
Self diagnosis
Interference device
The cause must be determined by the SMA Service Line.
Corrective measures:
• Contact the SMA Service Line.
6301
Self diagnosis
Interference device
The cause must be determined by the SMA Service Line.
Corrective measures:
• Contact the SMA Service Line.
Event
number
Display message
Cause and corrective measures