7  Commissioning

Installation - Quick Reference Guide

Ersatzstrom-IS-en-30

43

Set the number of Sunny Island inverters in the system:

1Phase: system with one Sunny Island inverter

3Phase: system with three

Sunny Island inverters

If the country data set of the Sunny Island inverter is

VDE-AR-4105 and the system increases self-consumption

(SelfConsBackup), set the type of feed-in of the PV system

(see Section 3.1, page 12).

If the system does not

increase self-consumption

(BackupOnly) or the

country data set of the

Sunny Island inverter is

AS4777, confirm the basic

configuration with Y.

Confirm the basic

configuration with Y.

Asymmetric: The

installation site is located in

Germany and at least one PV

inverter feeds in

asymmetrically on a single

line conductor.

Symmetric: The installation

site is either located outside

of Germany or all PV

inverters feed in

symmetrically on three line

conductors.

Wait until the upper LED

(inverter LED) on slave 1 is

flashing and the Sunny

Remote Control is displaying

To identify Slave1, press

Tss on the Slv.

Set the line conductor to

which the Sunny Island is

connected:

Confirm the basic

configuration with Y.

Press the start-stop button on

slave 1.

L1: connection to line

conductor L1

L2: connection to line

conductor L2

L3: connection to line

conductor L3

Confirm the basic

configuration with Y.

Wait until the upper LED

(inverter LED) on slave 2 is

flashing and the Sunny

Remote Control is displaying

To identify Slave2, press

Tss on the Slv.