Comparison: differences in program run, operation – HEIDENHAIN TNC 620 (73498x-01) User Manual
Page 537

HEIDENHAIN TNC 620
537
Comparison: Differences in Program Run,
operation
Function
TNC 620
iTNC 530
Arrangement of soft-key rows and soft
keys within the rows
Arrangement of soft-key rows and soft-keys varies depending on the active screen
layout.
Editing of program after program run
was interrupted by switching to the
Single block mode of operation.
The INTERNAL STOP soft key must also
be pressed to cancel the program
Editing is possible right after switching
to the Programming mode of operation
Operating-mode switchover after
program run was interrupted by
switching to the Single block mode of
operation
The INTERNAL STOP soft key must also
be pressed to cancel the program
Switching the operating mode is
allowed
Operating-mode switchover after
program run was interrupted by
switching to the Single block mode of
operation, and canceled by INTERNAL
STOP
on the TNC 620
When you return to the Program Run
mode of operation: Error message
Selected block not addressed
. Use
mid-program startup to select the point
of interruption
Switching the operating mode is
allowed, modal information is saved,
program run can be continued by
pressing NC start
GOTO is used to go to FK sequences
after program run was interrupted there
before switching the operating mode
Error message FK programming:
Undefined starting position
GOTO allowed
Mid-program startup:
Behavior after restoring the machine
status
The menu for returning must be
selected with the RESTORE
POSITION soft key
Menu for returning is selected
automatically
Completing positioning for mid-
program startup
After position has been reached,
positioning mode must be exited with
the RESTORE POSITION soft key
The positioning mode is automatically
exited after the position has been
reached
Switching the screen layout for mid-
program startup
Only possible, if startup position has
already been approached
Possible in all operating states
Error messages
Error messages are still active after the
error has been corrected and must be
acknowledged separately
Error messages are sometimes
acknowledged automatically after the
error has been corrected
Editing Q-parameter contents after
program run was interrupted by
switching to the Single block mode of
operation
The INTERNAL STOP soft key must also
be pressed to cancel the program
Direct editing possible
Manual traverse during program
interruption and with active M118
Function not available
Function available