12 preassigned q parameters, Values from the plc: q100 to q107, Active tool radius: q108 – HEIDENHAIN TNC 620 (73498x-01) User Manual
Page 297

HEIDENHAIN TNC 620
297
8.12 Pr
eassigned Q par
a
met
e
rs
8.12 Preassigned Q parameters
The Q parameters Q100 to Q199 are assigned values by the TNC. The
following are assigned to Q parameters:
Values from the PLC
Tool and spindle data
Data on operating status
Results of measurements from touch probe cycles etc.
The TNC saves the values for the preassigned Q parameters Q108,
Q114 and Q115 to Q117 in the unit of measure used by the active
program.
Values from the PLC: Q100 to Q107
The TNC uses the parameters Q100 to Q107 to transfer values from
the PLC to an NC program.
Active tool radius: Q108
The active value of the tool radius is assigned to Q108. Q108 is
calculated from:
Tool radius R (tool table or TOOL DEF block)
Delta value DR from the tool table
Delta value DR from the TOOL CALL block
Do not use preassigned Q parameters (or QS parameters)
between Q100 and Q199 (QS100 and QS199) as calculation
parameters in NC programs. Otherwise you might receive
undesired results.
The TNC remembers the current tool radius even if the
power is interrupted.