Overview, Datum setting in any axis – HEIDENHAIN TNC 620 (73498x-01) User Manual
Page 425

HEIDENHAIN TNC 620
425
13.8 D
a
tu
m set
ting with 3-D t
ouc
h pr
obe (T
ouc
h
P
ro
be
F
unction
sof
tw
a
re
option)
13.8 Datum setting with 3-D touch
probe (Touch Probe Function
software option)
Overview
The following soft-key functions are available for setting the datum on
an aligned workpiece:
Datum setting in any axis
U
Select the probe function by pressing the
PROBING POS soft key
U
Move the touch probe to a position near the touch
point.
U
Use the soft keys to select the probe axis and
direction in which you want to set the datum, such as
Z in direction Z–.
U
To probe the workpiece, press the machine START
button
U
Datum
: Enter the nominal coordinate and confirm your
entry with the SET DATUM soft key, see "Writing the
measured values from touch probe cycles in datum
tables", page 417
U
To terminate the probe function, press the END soft
key
Soft key
Function
Page
Datum setting in any axis
Setting a corner as datum
Setting a circle center as datum
Y
X
Z
HEIDENHAIN only gives warranty for the function of the
probing cycles if HEIDENHAIN touch probes are used.
If you use probing functions in a tilted working plane, you
must set 3-D ROT to Active for the Manual Operation and
Automatic operating modes.