beautypg.com

HEIDENHAIN 530 (340 49x-07) Cycle programming User Manual

Page 498

background image

498

Touch Probe Cycles: Automatic Kinematics Measurement

1

8

.5 PRESET COMPENSA

TION (Cy

c

le 452, DIN/ISO: G452, Option)

U

End angle B axis

Q416 (absolute): Ending angle in the

B axis at which the last measurement is to be made.
Input range -359.999 to 359.999

U

Angle of incid. in B axis

Q417: Angle of incidence

in the B axis at which the other rotary axes are to be
measured. Input range -359.999 to 359.999

U

Number meas. points B axis

Q418: Number of probe

measurements with which the TNC is to measure the
B axis. If the input value = 0, the TNC does not
measure the respective axis. Input range 0 to 12

U

Start angle C axis

Q419 (absolute): Starting angle in

the C axis at which the first measurement is to be
made. Input range -359.999 to 359.999

U

End angle C axis

Q420 (absolute): Ending angle in the

C axis at which the last measurement is to be made.
Input range -359.999 to 359.999

U

Angle of incid. in C axis

Q421: Angle of incidence

in the C axis at which the other rotary axes are to be
measured. Input range -359.999 to 359.999

U

Number meas. points C axis

Q422: Number of probe

measurements with which the TNC is to measure the
C axis. If input value = 0, the TNC does not measure
the respective axis. Input range 0 to 12

U

No. of measuring points

Q423: Specify the number

of probing points to be used by the TNC for
measuring the calibration sphere in the plane. Input
range: 3 to 8 measurements

U

Backlash, angle range

Q432: Here you define the

angle value to be used as traverse for the
measurement of the rotary axis. The traversing angle
must be significantly larger than the actual backlash
of the rotary axes. If input value = 0, the TNC does not
measure the backlash. Input range -3.0000 to
+3.0000