15.1
0
D
A
TUM CIR
C
LE CENTER (Cy
c
le
416, DIN/ISO: G416)
U
Datum number in table
Q305: Enter the number in the
datum or preset table in which the TNC is to save the
coordinates of the bolt-hole circle center. If you enter
Q305=0, the TNC automatically sets the display so
that the new datum is on the bolt hole center. Input
range 0 to 2999
U
New datum for reference axis
Q331 (absolute):
Coordinate in the reference axis at which the TNC
should set the bolt-hole center. Default setting = 0.
Input range -99999.9999 to 99999.9999
U
New datum for minor axis
Q332 (absolute):
Coordinate in the minor axis at which the TNC should
set the bolt-hole center. Default setting = 0. Input
range -99999.9999 to 99999.9999
U
Measured-value transfer (0, 1)
Q303: Specify
whether the determined datum is to be saved in the
datum table or in the preset table:
–1: Do not use. Is entered by the TNC when old
programs are read in (see “Saving the calculated
datum” on page 356).
0: Write determined datum in the active datum table.
The reference system is the active workpiece
coordinate system.
1: Write determined datum in the preset table. The
reference system is the machine coordinate system