HEIDENHAIN 530 (340 49x-07) Cycle programming User Manual
Page 336

336
Touch Probe Cycles: Automatic Measurement of Workpiece Misalignment
14.2 BA
SIC R
O
T
A
TION (Cy
c
le 40
0, DIN/ISO: G40
0
)
U
Traversing to clearance height
Q301: Definition of
how the touch probe is to move between the 
measuring points: 
0: Move at measuring height between measuring 
points
1: Move at clearance height between measuring 
points 
Alternatively PREDEF
U
Default setting for basic rotation
Q307
(absolute): If the misalignment is to be measured 
against a straight line other than the reference axis, 
enter the angle of this reference line. The TNC will 
then calculate the difference between the value 
measured and the angle of the reference line for the 
basic rotation. Input range -360.000 to 360.000
U
Preset number in table
Q305: Enter the preset
number in the table in which the TNC is to save the 
determined basic rotation. If you enter Q305=0, the 
TNC automatically places the determined basic 
rotation in the ROT menu of the Manual Operation 
mode. Input range 0 to 2999
Example: NC blocks
5 TCH PROBE 400 BASIC ROTATION
Q263=+10
;1ST POINT 1ST AXIS
Q264=+3.5 ;1ST POINT 2ND AXIS
Q265=+25
;2ND POINT 1ST AXIS
Q266=+8
;2ND POINT 2ND AXIS
Q272=2
;MEASURING AXIS
Q267=+1
;TRAVERSE DIRECTION
Q261=-5
;MEASURING HEIGHT
Q320=0
;SET-UP CLEARANCE
Q260=+20
;CLEARANCE HEIGHT
Q301=0
;MOVE TO CLEARANCE
Q307=0
;PRESET BASIC ROTATION
Q305=0
;NO. IN TABLE