HEIDENHAIN 530 (340 49x-07) Cycle programming User Manual
Page 374

374
Touch Probe Cycles: Automatic Datum Setting
15.6 D
A
TUM FR
OM INSIDE OF CIR
C
LE (Cy
c
le 412, DIN/ISO:
G412)
U
Measuring height in the touch probe axis
Q261
(absolute): Coordinate of the ball tip center (= touch 
point) in the touch probe axis in which the 
measurement is to be made. Input range 
-99999.9999 to 99999.9999
U
Set-up clearance
Q320 (incremental): Additional
distance between measuring point and ball tip. Q320 
is added to MP6140. Input range 0 to 99999.9999; 
alternatively PREDEF
U
Clearance height
Q260 (absolute): Coordinate in the
touch probe axis at which no collision between touch 
probe and workpiece (fixtures) can occur. Input range 
-99999.9999 to 99999.9999; alternatively PREDEF
U
Traversing to clearance height
Q301: Definition of
how the touch probe is to move between the 
measuring points: 
0: Move at measuring height between measuring 
points
1: Move at clearance height between measuring 
points
Alternatively PREDEF
U
Datum number in table
Q305: Enter the number in the
datum/preset table in which the TNC is to save the 
coordinates of the pocket center. If you enter 
Q305=0, the TNC automatically sets the display so 
that the new datum is at the center of the pocket. 
Input range 0 to 2999
U
New datum for reference axis
Q331 (absolute):
Coordinate in the reference axis at which the TNC 
should set the pocket center. Default setting = 0. 
Input range -99999.9999 to 99999.9999
U
New datum for minor axis
Q332 (absolute):
Coordinate in the minor axis at which the TNC should 
set the pocket center. Default setting = 0. Input range 
-99999.9999 to 99999.9999
U
Measured-value transfer (0, 1)
Q303: Specify
whether the determined datum is to be saved in the 
datum table or in the preset table:
–1: Do not use. Is entered by the TNC when old 
programs are read in (see “Saving the calculated 
datum” on page 356).
0: Write determined datum in the active datum table. 
The reference system is the active workpiece 
coordinate system.
1: Write determined datum in the preset table. The 
reference system is the machine coordinate system 
(REF system).
X
Z
Q261
Q260
MP6140
+
Q320