beautypg.com

HEIDENHAIN iTNC 530 (340 49x-06) User Manual

Page 712

background image

M109

M110

M111

Constant contouring speed at tool cutting edge
(increase and decrease feed rate)
Constant contouring speed at tool cutting edge
(feed rate decrease only)
Reset M109/M110

„

„

„

Page 368

M114
M115

Automatic compensation of machine geometry when working with tilted axes
Reset M114

„

„

Page 481

M116
M117

Feed rate for rotary axes in mm/min
Reset M116

„

„

Page 478

M118 Superimpose handwheel positioning during program run

„

Page 371

M120 Pre-calculate radius-compensated contour (LOOK AHEAD)

„

Page 369

M124 Do not include points when executing non-compensated line blocks

„

Page 362

M126
M127

Shortest-path traverse of rotary axes
Reset M126

„

„

Page 479

M128
M129

Retain position of tool tip when positioning tilting axes (TCPM)
Reset M128

„

„

Page 482

M130 Moving to position in an untilted coordinate system with a tilted working plane

„

Page 360

M134
M135

Exact stop at nontangential contour transitions when positioning with rotary axes
Reset M134

„

„

Page 485

M136
M137

Feed rate F in millimeters per spindle revolution
Reset M136

„

„

Page 367

M138 Selection of tilted axes

„

Page 485

M140 Retraction from the contour in the tool-axis direction

„

Page 372

M141 Suppress touch probe monitoring

„

Page 373

M142 Delete modal program information

„

Page 374

M143 Delete basic rotation

„

Page 374

M144

M145

Compensating the machine’s kinematics configuration for ACTUAL/NOMINAL positions at
end of block
Reset M144

„

„

Page 486

M148
M149

Retract the tool automatically from the contour at NC stop
Reset M148

„

„

Page 375

M150 Suppress limit switch message (function effective blockwise)

„

Page 376

M200
M201
M202
M203
M204

Laser cutting: Output programmed voltage directly
Laser cutting: Output of voltage as a function of distance
Laser cutting: Output of voltage as a function of speed
Laser cutting: Output of voltage as a function of time (ramp)
Laser cutting: Output voltage as a function of time (pulse)

„
„
„

„
„

Page 377

M

Effect

Effective at block... Start

End

Page