Application

Press the CHECK THE FILE SYSTEM soft key to check the TNC and
PLC partitions on the hard disk, and have them automatically be
repaired if necessary.

Performing the data carrier check

U

Press the MOD key to select the MOD function.

U

To select the diagnostic functions, press the

DIAGNOSIS soft key

U

To start the data carrier test, press the CHECK THE

FILE SYSTEM soft key

U

Press the YES soft key again to confirm that the check

should be started. This function shuts down the TNC
software and starts checking the data carrier. This
check can take some time, depending on the number
and size of the files that you have stored on the hard
disk

U

At the end of the test the TNC displays a window with

the results of the test. The TNC also writes the results
to the system log

U

In order to restart the TNC software, press the ENT

key

The TNC’s system partition is automatically checked each
time the control is started. If any errors are found on the
system partition, the TNC reports this with an error
message.

Danger of collision!

Before starting the data carrier check, put the machine in
the EMERGENCY STOP condition. The TNC restarts the
software before performing the check!