5 4

C

y

cles f

o

r

Coordinate T

ransf

ormations

SCALING (11)

CYCL DEF: Select Cycle 11 SCALING

Enter the scaling factor (SCL):

• Input range 0.000001 to 99.999999:

To reduce the contour ... SCL < 1

To enlarge the contour ... SCL > 1

To cancel the SCALING, re-enter the cycle definition with SCL1.

11 CALL LBL1
12 CYCL DEF 7.0 DATUM SHIFT
13 CYCL DEF 7.1 X+60
14 CYCL DEF 7.2 Y+40
15 CYCL DEF 11.0 SCALING
16 CYCL DEF 11.1 SCL 0.75
17 CALL LBL1

SCALING can be effective in the working plane only or in all

three main axes (depending on machine parameter 7410)!