beautypg.com

2 0 path functions – HEIDENHAIN TNC 310 (286 140) Pilot User Manual

Page 20

background image

2 0

Path Functions

Inserting a Chamfer Between Two Straight Lines

Chamfer side length

Feed rate F for the chamfer

Corner Rounding

The beginning and end of the arc extend tangentially from the previous

and subsequent contour elements.

Radius R of the circular arc

Feed rate F for corner rounding

7 L X+0 Y+30 RL F300 M3
8 L X+40 IY+5
9 CHF 12
10 L IX+5 Y+0

• You cannot start a contour with a CHF block.

• The radius compensation before and after the CHF block

must be the same.

• An inside chamfer must be large enough to accommodate

the current tool.

5 L X+10 Y+40 RL F300 M3
6 L X+40 Y+25
7 RND R5 F100
8 L X+10 Y+5

An inside arc must be large enough to accommodate the

current tool.