beautypg.com

HEIDENHAIN ND 1300 CNC Setup User Manual

Page 35

background image

2

3

CNC Setup

CNC test functions for a single axis

Individual axes are adjusted and tested using the CNC Setup screen before vector moves are attempted with

multiple axes. Test functions include:

Test distance
An axis test consists of the CNC move on the current axis. The test distance

is entered into the test distance field in millimeters or inches before starting

the test.

Set home

Touch the Set home button to set the current position of the stage to home (zero). Test moves

are made from this home position to the specified test distance.

Test

Touch the Test button to initiate a test move. Repeatedly touching the Test button alternately

moves the stage from home to the

Test distance and from the Test

distance back to home. Observe the axis motion

and position on the CNC Setup screen.

CAUTION

Axes can move very quickly. To avoid damage to the equipment, when performing

a test, be prepared to touch the Stop button. If an axis begins to run away, touch the

Stop button immediately.

Stop

Touch the Stop button to halt axis motion.

CAUTION

The Stop button is not intended as a substitute for hard-contact emergency stop

switches. Touching the Stop button is a convenient way to halt axis motion, but do

not rely completely on this software interface - always be prepared to use the emer-

gency stop button to halt motion.

Observe the axis motion and position

PID Loop Tuning - Single Axis Test Functions