Joystick setup and calibration

The Joystick screen contains fields calibrating and con-

figuring joystick motion.

Enabling joystick motion

Check an axis Enable box

to enable joystick motion,

or clear the box to disable joystick

motion on that axis.

Teaching the Joystick range of motion

The system must measure the joystick range of motion before the

joystick can be used. Touch the Teach button to start the calibration

procedure, and then follow the instructions displayed on the screen.

Joystick positions will be indicated by Max(v), Center(v), Min(v) and

Current(v) voltage values.

Deadband

A deadband area of joystick inactivity is specified around the zero position of each axis to eliminate errone-

ous axis motion due to joystick vibration or noise. The default values are expressed as percentages of total

motion and will satisfy the requirements of most environments, however

these values can be increased or decreased by selecting the deadband field

and entering the desired value.

Reversed axis direction

The direction of motion controlled by the joystick on an axis can be reversed

to accommodate different joystick and system hardware by checking the Re-

versed axis box.