beautypg.com

Programming the trigger points – HEIDENHAIN ND 760 E User Manual

Page 18

background image

18

Programming the Trigger Points:

1st trigger point before MIN position:

Switching output A1

Input range: 0 to 99 999.9999 mm

MIN. TP. 1

1st trigger point before reaching the erosion depth:

Switching output A3

Input range: 0 to 99 999.9999 mm

TRIG. PNT. 1

2nd trigger point before reaching the erosion depth:

Switching output A4

Input range: 0 to 99 999.9999 mm

TRIG. PNT. 2

Additional trigger point TP3:

Switching output A6 (depends on

parameter P21)

Input range: -99 999.9999 to

99 999.9999 mm

TRIG. PNT. 3

Additional switching point TP4:

Switching output A7 (depends on

parameter P21)

Input range: -99 999.9999 to

99 999.9999 mm

TRIG. PNT. 4

Trigger point for erosion depth:

Switching output A5

Input range: -99 999.9999 to

99 999.9999 mm

ER. DEPTH

Start position (HOME position):

Switching output A6 (depends on

parameter P21)

Input range: -99 999.9999 to

99 999.9999 mm

START POS.

After the respective trigger point has been called, the

currently valid value is displayed in the Y axis. You can enter a

new value with the numerical keys and transfer it with the

ENT key. To cancel this operating mode, press the SHIFT or

the CLkey.

The second trigger point before the MIN position is

programmed in parameter P17 (or P18).

Programming

the

Trigger

Points

Bateil1.pm6

21.01.2002, 09:39

18