Programming the trigger points – HEIDENHAIN ND 760 E User Manual
Page 18

18
Programming the Trigger Points:
1st trigger point before MIN position:
Switching output A1
Input range: 0 to 99 999.9999 mm
MIN. TP. 1
1st trigger point before reaching the erosion depth:
Switching output A3
Input range: 0 to 99 999.9999 mm
TRIG. PNT. 1
2nd trigger point before reaching the erosion depth:
Switching output A4
Input range: 0 to 99 999.9999 mm
TRIG. PNT. 2
Additional trigger point TP3:
Switching output A6 (depends on
parameter P21)
Input range: -99 999.9999 to
99 999.9999 mm
TRIG. PNT. 3
Additional switching point TP4:
Switching output A7 (depends on
parameter P21)
Input range: -99 999.9999 to
99 999.9999 mm
TRIG. PNT. 4
Trigger point for erosion depth:
Switching output A5
Input range: -99 999.9999 to
99 999.9999 mm
ER. DEPTH
Start position (HOME position):
Switching output A6 (depends on
parameter P21)
Input range: -99 999.9999 to
99 999.9999 mm
START POS.
After the respective trigger point has been called, the
currently valid value is displayed in the Y axis. You can enter a
new value with the numerical keys and transfer it with the
ENT key. To cancel this operating mode, press the SHIFT or
the CLkey.
The second trigger point before the MIN position is
programmed in parameter P17 (or P18).
Programming
the
Trigger
Points
Bateil1.pm6
21.01.2002, 09:39
18