beautypg.com

Switch-on, traversing the reference marks, 0 è 1 – HEIDENHAIN ND 760 E User Manual

Page 12

background image

12

Switch-on, Traversing the Reference Marks

ENT...CL

Turn on power (switch located on rear panel). REF

in the status display starts blinking.

Confirm reference traverse mode. REF indicator

stops blinking and stays on. Decimal points blink.

Cross over the reference marks in all axes (in any

sequence). Each axis display becomes active when

its reference mark is crossed over.

0 è 1

ENT

Crossing over the reference marks stores the most recently defined

assignment of display values to axis slide positions for datum points 1

and 2 in nonvolatile memory.

Note that if you choose not to traverse the reference marks (by clearing

the dialog ENT ... CL with the CL key), this relationship will be lost if the

power is interrupted or when the unit is switched off.

Switch-on,

Traversing

the

Reference

M

arks

If you wish to use multipoint axis error compensation, you

must traverse the reference marks (see “Multipoint axis error

compensation”)!

Bateil1.pm6

21.01.2002, 09:39

12