10

Nominal position, actual position and distance-to-go
The position to which the tool is to move is called the nominal position
(

S

). The position at which the tool is actually located at any given

moment is called the actual position (

I

).

The distance from the nominal position to the actual position is called the
distance-to-go (

R

).

Sign for distance-to-go
When you are using the distance-to-go display, the nominal position

becomes the relative datum (display value 0). The distance-to-go is

therefore negative when you move in the positive axis direction, and

positive when you move in the negative axis direction.