Grass Valley T2 Classic iDDR User Manual
Page 108

108
T2 Users Manual –SP3/SP4–
October 17, 2011
Chapter 6 Additional/Updated Functions for SP3 and SP4
7. Select "Exit Saving Changes", and then press the [Enter] key on the keyboard.
8. Select [Yes] on the confirmation dialog box, and then press the [Enter] key on the
keyboard.
9. Restart your T2 in the maintenance mode.
• If you use the LAN2 terminal, the Wake On LAN function is enabled. Proceed
"Step 2: To check the MAC address/IP address of the NIC" on page 108
.
10. In the
Start
menu, right-click
My Computer
, and then click
Properties
.
11. Click the
Hardware
tab, and then click
Device Manager
.
12. Click the "Network adaptors" tree.
13. Right-click
Intel(R) 82567LM-3 Gigabit Network Connection
, and then click
Properties
.
• The network adapter for the LAN1 terminal is Intel(R) 82567LM-3 Gigabit
Network Connection. The network adapter for the LAN2 terminal is Realtec
RTL 8168C(P)8111(P) PCI-E Gigabit Ethernet NIC.
14. Click the
Advanced
tab, and then change the settings to the following:
(1)Click "Wake on Settings" in "Property:", and then select Wake on Magic Packet
from the "Value:" list.
(2)Click "Enable PME" in "Property:", and then select Enabled from the "Value:" list.
15. Click the
Power Management
tab, and then check
Allow this device to bring the
computer out of standby
.
Step 2: To check the MAC address/IP address of the NIC
1. Restart your T2 in the maintenance mode.
2. Execute ipconfig /all at the command prompt.
3. Check the MAC address, the IP address, and the subnet mask.
Step 3: To turn on your T2 by sending packets from the PC
Send packets from your T2 to the PC using the MAC address, the IP address, and the
subnet mask checked in Step 2.
Turn off your T2 and confirm that the network cable is connected to the LAN1
terminal or the LAN2 terminal beforehand.
1. Send Magic Packet via network.