Grass Valley SSP-3801 Installation v.1.3 User Manual
Page 26

22
Installing the SSP-3801 card
Installing a second on-board solid state storage drive
Figure 3-4. positions of the SSDs
To install the second SSD:
1 Log into the card’s web interface. For more information see
2 Obtain and enable the OPT 2SSD license. For information about how to enable a
license, see “Enabling or disabling a license option” in the User Guide.
3 From the menu, select Restart and click Safe Shutdown.
4 Once shutdown is complete, remove the SSP-3801 card from the Densité 3 frame.
5 Install the second SSD:
• Locate the first SSD in between the front and rear of the card. The second SSD is
installed next to the first SSD.
• Hold the SSD so that the SATA connectors are in the correct position to align with
the connectors on the rear of the card.
• Carefully insert the second SSD into position beside the first SSD and slide it into
the connectors ensuring that the connection is well made.
• Screw the SSD into place with the screws provided.
6 Replace the SSP-3801 card into the Densité 3 frame.
7 When the card has rebooted, verify that the SSD was installed correctly. To verify:
• Open and log into the SSP-3801 card’s web interface (see
• From the menu, select Status Information > System and click Partitions. In the
Media Cache Partition
section, the size should include the combined amounts of
First SSD
Location to install
the second SSD