3 configuration – Grass Valley RCP-10x0 User Manual
Page 8

GUIDE TO INSTALLATION AND OPERATION
4 | RCP-10x0
3 Configuration
The RCP-10x0 remote control panel is configured with the use of an on-board web server.
Access to the web server requires the user to enter the RCP-10x0’s IP address in the browser’s address
window. This IP address will vary with the current operating mode of the RCP-10x0.
3.1 Operating
Modes
The RCP-10x0 can be placed in one of two modes, using rear-panel DIP switches. The web server
configuration pages are available in both modes, but the modes differ in several respects:
• Configuration mode – the web interface has a fixed IP address and the panel cannot be used to
control a router.
• Operation mode – the panel can be used to operate a router. The web interface IP address may be
variable, and a system log of information, warning and errors is maintained as a troubleshooting tool.
See section 4 for information about the OPERATION mode, and instructions for operating the
RCP-10x0.
A bank of 4 DIP switches is accessible on the back panel.
Switch
Description
Function
SW1
Operation/Config
OPERATION panel is in normal operation mode
CONFIG: panel is in configuration mode
SW2
Router/Client
ROUTER: operate an HRS-1801 Densité router
CLIENT: (future use)
SW3 Spare
SW4 Spare
In order to configure the router, the user must access its web server using a browser.
• In CONFIG mode, the router’s IP address is fixed to a factory-defined value
• In OPERATION mode, the IP address may be fixed or dynamic, and the fixed address is user-
settable
Exiting the factory, the panel will be in CONFIG mode with the following IP parameters.
ON
2
3
4
1