beautypg.com

Grass Valley RCP-10x0 User Manual

Page 29

background image

GUIDE TO INSTALLATION AND OPERATION

RCP-10x0 | 25

Densité Chassis to connect to using a hostname, you must specify a valid DNS server. If you are using
an IP address to specify the Densité Chassis to connect to, the DNS doesn’t need to be valid; it is
ignored by the panel.


4. In the Densité Chassis section, enter the IP address or hostname of the Densité Chassis where the

HRS-1801 you want to control is located, and specify the slot number in which the OUTPUT card of the
HRS-1801 is installed.


For more information on the setup page, see Section 3.4 beginning on page 6.

5. Click the Apply button at the bottom of the web page. The panel should display a confirmation screen:


If some parameters are invalid, the confirmation screen will report an error:


While this message is being displayed on the browser, the panel is rebooting. After the timeout, the setup
page should come back up on the browser (even if you set up the panel to use DHCP in OPERATION mode
because we are now in CONFIGURATION mode, therefore the IP parameters are fixed).