Grass Valley RCP-10x0 User Manual
Page 13

GUIDE TO INSTALLATION AND OPERATION
RCP-10x0 | 9
You must enter:
• The IP address of the Densité frame in which the router is installed
• The slot number of the router output card in that frame
• The control panel ID
o
Enter a unique number to identify this control panel (range 1-250)
• The first source to control (pulldown listing all available sources)
o
If the control panel is able to control fewer sources than are attached to the router, select
which source is the first to control
o
For example, an RCP-1020 is operating a 40-input router. The RCP will control 20 consecutive
sources beginning with the number entered, so if 18 is entered, the control panel will operate
the router as if it is a 20-input router with sources 18 to 37 as its inputs
o
In Dual or Quad bus mode, this identifies the first source in the controlled range (see sect.4.7)
3.4.4 Appearance
Use the three pulldowns to select the brightness of the LEDs that illuminate the control panel buttons and the
slide-in label strip between the rows of pushbuttons.
Choices are:
• HIGH intensity
- set the level of brightness that corresponds to High intensity in operation
• LOW intensity
- set the level of brightness that corresponds to Low intensity in operation
• LEGEND intensity
- set the level of illumination for the slide-in label strip (see Section 3.7)
All three pulldowns allow the level to be set from 0% to 100% in steps of 5%
3.4.5 Disabled
buttons
Click in the box for any control panel button to disable it
• The button will be OFF and non-functional when disabled
• This only affects the RCP-10x0; the router itself is not affected