Grass Valley RCP-10x0 User Manual
Page 12

GUIDE TO INSTALLATION AND OPERATION
8 | RCP-10x0
Bus number (1-4) – enter the following data, depending on the mode selected in the pulldown
• Single bus mode – the number of the bus that is to be controlled
• Dual bus mode – enter the number of the first bus to be controlled (possible values 1, 2 or 3)
o
the RCP-10x0 will control that bus and the next one
• The default value is 1
3.4.2 Ethernet
Interface
Select the IP addressing mode using the pulldown.
The available choices are:
• DHCP
use dynamic network addressing. When selected, it allows a server to dynamically attribute an IP
address and configuration information to the RCP-10x0. Normally the DHCP server provides at least
the following basic information: IP address, subnet mask and default gateway. When "DHCP" is
chosen, the fixed network parameters are not used unless a DHCP server cannot be found. DNS
servers are usually also reported by the DHCP server (2 are reported but only the primary server is
displayed in the web page)
• Fixed
forces the RCP-10x0 to use the attributes entered in the Fixed IP Mode data boxes. The user should
consult the network manager if unfamiliar with the requirements for this data.
o
Enter data for the four listed Fixed IP Mode network parameters
The MAC address is a unique identifier for this specific device, and is not user-configurable.
3.4.3 Densité
Chassis
Enter the information that identifies the router that the RCP-10x0 will control.