GUIDE TO INSTALLATION AND OPERATION
RCP-10x0 | 17
1. PANEL ENABLE
2. DESTINATION (or BUS) LOCK
3. TAKE
4. DESTINATION (or BUS) PROTECT
4.6.1
PANEL ENABLE button
The PANEL ENABLE button has three primary functions:
1. To correctly disconnect the RCP-10x0 from the Densité controller in the frame containing the router
:
• To disable and disconnect the RCP-10x0 from the router, push and hold the PANEL ENABLE button
for 5 seconds while the panel is enabled. This will properly disconnect the panel from the Densité
controller. The ethernet cable can then be unplugged from the RCP-10x0
• Failure to do so when disconnecting a panel from a DENSITE-CPU-ETH could lead the controller in
thinking the connection to the panel is still valid. This would render the only connection on this
controller unusable and require a reset of the controller.
2. The Panel Enable button is used to temporarily disable the other control panel buttons, protecting
against accidental crosspoint selections. The status of the inputs is still shown by the source buttons.
3. The button is used to announce that the panel is initializing.
• When the panel is initializing, all button actions are ignored and all LEDs are off except for the
PANEL ENABLE button, which is slowly flashing.
Green
Red
Colors
Amber
This button is always amber.
Off
The panel is unpowered.
Low
Panel is disabled.
• If source buttons are dimmed low, their colors represent
the state of the specific source.
• If the source buttons are off, the panel is disabled AND
properly disconnected from the Densité controller and the
HRS-1801.
All other buttons are off.
Intensities
High
The panel is enabled and initialized.
None Normal
operation
Slow
The panel is initializing. If this button is always flashing,
check the error log on the web interface.
PANEL
ENABLE
button
Flashing
Fast
If the panel is disabled and any other button is pressed, this
button flashes for 1 second.
2
1
4
3