Grass Valley RCP-10x0 User Manual
Page 19

GUIDE TO INSTALLATION AND OPERATION
RCP-10x0 | 15
• The source buttons are assigned to 10 consecutive sources, beginning with a source that is specified
in the configuration
• Push the source button to activate the crosspoint
4.2
Label strip illumination:
The label for each active button is backlit by a white LED
• The label illumination for an inactive button is OFF
• The intensity of all active label illumination LEDs is the same, and is set in the Setup tab of the
configuration web page (see section 3.4.4)
4.3 Configuration
persistency
All configuration parameters are saved in non-volatile memory. Upon a power failure, brownout or reset, the
saved configuration parameters are reloaded. If the DIP switch is changed while the power is on, the panel
will switch to the appropriate mode immediately.
4.4 Source
buttons
The source selection buttons control N consecutive sources, where N is the number of source buttons
available on the panel.
Green
If the Clean Switch option is available AND activated on the
HRS-1801, green means that the signal is within the timing
window to perform a clean switch.
Red
No signal is present at this position
Colors
Amber
If the Clean Switch option is available AND activated on the
HRS-1801, amber means that the signal is outside the timing
window to perform a clean switch.
Off
Button is not used in the current configuration
Low
The source is not selected for the bus (single, dual or quad bus
mode) or the selected destination (XY modes)
Intensities
High
This source is routed to the output bus (single, dual or quad
bus mode) or to the selected destination (XY modes)
None Normal
operation
Slow
The source is preset for a pending take (XY modes)
Any
SOURCE
button
Flashing
Fast
The user asked for a cross point that cannot be activated
(may be inhibited, locked, etc.).