beautypg.com

Grass Valley RCP-10x0 User Manual

Page 18

background image

GUIDE TO INSTALLATION AND OPERATION

14 | RCP-10x0

4.1 Operating

Modes


The panel may be configured in any of the following operating modes:

RCP-1010

RCP-1020

RCP-1030

RCP-1040

Single Bus

Single Bus

Single Bus

Single Bus

XY – Without Preset

Dual 10x1 Bus

XY – Without Preset

Dual 20x1 bus

XY – With Preset

XY – Without Preset

XY – With Preset

Quad 10x1 bus

XY – With Preset

XY – Without Preset

XY – With Preset

4.1.1

XY without preset mode

• Operates as an Nx4 router, with N being the number of sources supported (e.g. RCP-1020 supports

20 sources)

• Select the destination, then push the source button to activate the crosspoint

4.1.2

XY- with preset mode

• Operates as an Nx4 router, with N being the number of sources supported (e.g. RCP-1040 supports

40 sources)

• Select the destination, then push the source button to preset a switch

• Push TAKE to activate the crosspoint

4.1.3

Single Bus mode

• The destination bus is pre-selected in the configuration and the panel operates only that bus on the

router

• Push the source button to activate the crosspoint

4.1.4

Dual Bus mode

• The panel is configured to control two consecutive destination buses on the router (e.g. 1 & 2, 2 & 3

or 3 & 4)

• The upper row of source buttons is assigned to the first controlled bus

• The lower row of source buttons is assigned to the second controlled bus

• The source buttons are assigned to M consecutive sources, where M is the scale of the Dual Bus

mode (e.g. 20x1 can control 20 consecutive sources)

• The first controlled source is specified in the configuration.

• Push the source button to activate the crosspoint

4.1.5

Quad Bus Mode

• The panel is configured to control all four output busses of the router (only available with RCP-1040)

• The panel source buttons are assigned to the buses in groups of 10, each being half of the upper or

lower row