Grass Valley Maestro Master Control Reference Manual v.2.4.0 User Manual
Page 61

MAESTRO — Automation Interface Protocol Technical Reference Manual
61
RECALL_REG (Recall configured independent transition)
RECALL_REG (Recall configured independent transition)
This command allows Saturn's distributed transition parameters to be preset using the customer's predefined configura
tion sets.
Hex definition
Mnemonic
E4
RECALL_REG
Command format:
RECALL_REG
Query format:
READ RECALL_REG
Reply format:
IFRE RECALL_REG
Note: The response will contain a reply for each board requested in the
within a begin-end construct.
Use applicable with UPDATE:
Yes
Argument definitions:
<
register_bits> = 00, 10 (hex, one byte)
00 =
Valid on query only--verify existence of transition table specified in
in the reply, then the table exists in the customer's configuration set.)
10 =
(Bit 4 set--all other bits reserved) Recall transition configuration table.
<register_number> = 00, 01-63, 64, 65 (hex, one byte)
Specifies the configuration transition table number, or reports on the current table on a reply.
00 = Specifies default transition parameters.
01-63 = Specifies configuration transition table numbers 1-99.
64 = Valid on reply only--reports that transition parameters have been set by TRAN_PRESET.
65 = Valid on reply only--reports that transition parameters have been manually set.