MAESTRO — Automation Interface Protocol Technical Reference Manual
Section 5 — Definition of Extended Maestro Commands
MAESTRO_KEYER_CLIP
Hex definition
Mnemonic
0x31
MAESTRO_KEYER_CLIP
Command format:
MAESTRO_KEYER_CLIP
Query format:
READ
MAESTRO_KEYER_CLIP
Reply format:
IFRE
MAESTRO_KEYER_CLIP
Use applicable with UPDATE:
Yes
Argument definitions:
<keyer> = 1-8
1= Keyer 1
MAESTRO_KEY_01
2= Keyer 2
MAESTRO_KEY_02
3= Keyer 3
MAESTRO_KEY_03
4= Keyer 4
MAESTRO_KEY_04
5= Keyer 5
MAESTRO_KEY_05
6= Keyer 6
MAESTRO_KEY_06
7= Keyer 7
MAESTRO_KEY_07
8= Keyer 8
MAESTRO_KEY_08
<clip> = 0-0x03E8 (2 hex bytes, MSB first). The range is from 0.0% to 100% in 0.1 increments. 0 to 0x03E8 corresponds
to 0.0% to 100.0%.