beautypg.com

Grass Valley Maestro Master Control Reference Manual v.2.4.0 User Manual

Page 43

background image

MAESTRO — Automation Interface Protocol Technical Reference Manual

43

rate:

0,1-5

0 = Transition rate NOP
1 = Slow
2 = Medium
3 = Fast
4 = Cut
5 = Custom (used with argument to specify transition rate)

rate_SS:FF:

delay_SS:FF:

black_SS:FF:

seconds:

FF,00-09 (hex, one byte)

FF = argument NOP, causes Saturn to ignore the contents of the pair
00-09 = Seconds representing 0:00-9:00

frames:

00-1D (hex, one byte)

00-1D = Frames representing 0:00-0:29