MAESTRO — Automation Interface Protocol Technical Reference Manual

49

CEXT (0x3F) Common Extension

CEXT (0x3F) Common Extension

The Extension Set command UPDATE (0x07) is used to specify Saturn commands for auto-
matic updates. E.g.:

STX | LEN | 3F | 07 | 01 | 58 | 78 | 02 |

This would active UPDATE for AUD_PSET and REM_MODE. The RBGN/REND is neces-
sary since this example selects more than one command for updates.

The MUTE command would switch off all responses (Legacy or Maestro).