MAESTRO — Automation Interface Protocol Technical Reference Manual

Section 5 — Definition of Extended Maestro Commands

MAESTRO_TAKE_BLACK

Hex definition

Mnemonic

0x44

MAESTRO_TAKE_BLACK

Command format:

MAESTRO_TAKE_BLACK

Query format:

N/A

Reply format:

See MAESTRO_TRANSITION_STATE

Use applicable with UPDATE:

No

Argument definitions:

<toFrom> =

1 = Take to Black

MAESTRO_TO

2 = Take from Black MAESTRO_FROM

<requestedTransitionTimecode> (four BCD bytes or set all four bytes to FF for immediate Transition) =

0-23

HH

= packed BCD Hours

0-59

MM

= packed BCD Minutes

0-59

SS

= packed BCD Seconds

0-29

FF

= packed BCD Frames

Usage notes:

The requested Transition Time Code can be up to 12 hours in the future. A requested Time Code that is 12 hours or more
in the future will result in an immediate Transition.