MAESTRO — Automation Interface Protocol Technical Reference Manual

Section 4 — Definition of Supported Saturn Commands

(0x3F) Common Extension

The Extension Set command UPDATE (0x07) is enhanced to specify Maestro commands.
Extension (0xFF) precedes each Maestro command (I/F name). E.g.:

STX | LEN | 3F | 07 | 01 | FF | 40 | FF | 41 | 02 |

This would activate

UPDATE

for

MAESTRO_TRANSITION_TYPE and

MAESTRO_TRANSITION_RATE

The MUTE command would switch off all responses (Legacy or Maestro).