beautypg.com

Maestro_preroll_duration – Grass Valley Maestro Master Control Reference Manual v.2.4.0 User Manual

Page 136

background image

136

MAESTRO — Automation Interface Protocol Technical Reference Manual

Section 5 — Definition of Extended Maestro Commands

MAESTRO_PREROLL_DURATION

Hex definition

Mnemonic

0x4B

MAESTRO_PREROLL_DURATION

Command format:

MAESTRO_PREROLL_DURATION

Query format:

READMAESTRO_PREROLL_DURATION

Reply format:

IFRE MAESTRO_PREROLL_DURATION

Use applicable with UPDATE:

Yes

Argument definitions:

(unsigned two bytes) = seconds:frames

Notes

For a 30 frame video standard, the valid range for Pre Roll time is from 0 seconds and 0 frames (0:00) to 9 seconds and 29
frames (9:29). For a 25 frame video standard, the valid range for Pre Roll time is from 0 seconds and 0 frames (0:00) to 9
seconds and 24 frames (9:24). If there is a Pre Roll time entered in the GPIO Definition Table, then an entry of a Pre Roll
time outside the valid range will result in the Pre Roll Duration defaulting back to the Pre Roll time from the GPIO defini-
tion table. If there is not a Pre Roll time entered in the GPIO Definition Table, then an entry of a Pre Roll time outside the
valid range will result in an error message being reported (that is, the command will not be executed).