Numerical command cross reference – Grass Valley Maestro Master Control Reference Manual v.2.4.0 User Manual
Page 35

MAESTRO — Automation Interface Protocol Technical Reference Manual
35
Numerical command cross reference
Numerical command cross reference
Hex
Command
C/R/U
Explanation
0x44
TX_TRIG
C/-/-
Transition trigger
0x45
TX_STAT
-/R/U
Transition status
0x48
VID_PSET
C/R/U
Video PST bus take
0x49
VID_SYNC
-/R/-
Video sync status
0x4A
VID_1KEY
C/R/U
Key 1 source and parameters
0x4C
VID_MODE
C/R/U
Transition type select
0x4D
VID_RATE
C/R/U
Transition rate select
0x4E
VID_2KEY
C/R/U
Key 2 source and parameters
0x50
SEL_1KEY
C/R/U
Key 1 bus take
0x51
SEL_2KEY
C/R/U
Key 2 bus take
0x58
AUD_PSET
C/R/U
Audio PST bus take
0x5A
PST_OVER
C/R/U
PST over take
0x5B
PGM_OVER
C/R/U
PGM over take
0x61
REM_MODE
C/R/U
Remote switch
0x76
ALL_STOP
C/-/-
Cut to new video
0x78
FTBLK
C/R/U
Fade to black
0x79
RFTB
C/-/-
Return from fade to black
0x7F
TAKE_XPT
C/R/U
Bus take
0x90
CLK
C/R/-
Clock time
0x91
PROLL
C/R/U
Preroll time
0xA1
LRS_PST
C/R/U
PST audio mode
0xA3
LRS_PGM
C/R/U
PGM audio mode
0xA4
MAL_PST
C/R/U
PST main audio level
0xA7
MAL_PGM
C/R/U
PGM main audio level
0xAA
RATIO
C/R/U
Over to main ratio
0xAB
SAP0_PST
C/R/U
SAP0 PST level
0xAC
SAP1_PST
C/R/U
SAP1 PST level
0xAD
SAP0_PGM
C/R/U
SAP0 PGM level
0xAE
SAP1_PGM
C/R/U
SAP1 PGM level
0xC0
VID_BPSET
C/R/U
Backup video PST bus take
0xC1
AUD_BPSET
C/R/U
Backup audio PST bus take
0xC2
SWAP_PST
C/-/-
Swap primary and backup PST inputs
0xC3
SWAP_PGM
C/-/-
Swap primary and backup PGM inputs
0xE1
SET_MIX
C/R/U
Mixer related parameters
0xE0
SET_KEY
C/R/U
Keyer related parameters
0xE2
SET_AUDIO
C/R/U
Channel related audio parameters
0xE3
TRAN_PRESET
C/R/U
Distributed transition parameters
0xE4
RECALL_REG
C/R/U
Recall configured independent transition
`C' = Used as a Command
`R' = Used as a READ command
`U' = Can be used with UPDATE command
`-' = not applicable as a command or a Read command, as indicated
`*' = required argument to a READ command message