Kayenne XL Package — Installation and Service Manual
95
AUX Control Panels
Panel Connectors
The rear panels of each CP-300 and CP-330 control panels are identical.
Each one has a power receptacle on the left side for input from the +5V DC
supply. Two MPK bus connectors are adjacent for looping the common
control panel cable from unit to unit and to the switcher mainframe or main
panel.
Figure 67. Aux Control Panel Rear CP-300/330
The rear panel of the CP-3020 control panel has a power receptacle on the
left side for input from the AC power supply.
Two MPK bus connectors DATA A are adjacent for looping the common
control panel cable from unit to unit and to the switcher mainframe. The
remote connector is used for connecting the CP-3021 expansion module.
Figure 68. Aux Control Panel Rear CP-3020
The CP-3021 expansion panels are connected directly to the CP-3020 main
control panel module on a proprietary parallel bus. Two connectors are
provided to easily daisy-chain multiple expansion modules (max. 4) to the
main panel. The CP-3021 expansion panels need no separate power supply.
Figure 69. Aux Control Panel Rear CP-3021