Customer supplied ethernet routers and switches, Factory default network settings – Grass Valley Kayenne XL Package Installation v.7.0.4 User Manual
Page 82

82
Kayenne XL Package — Installation and Service Manual
Section 4 — System Cabling
Customer Supplied Ethernet Routers and Switches
Existing facility Ethernet switches can be used in conjunction with a
Kayenne XL/Kayak HD system. If connecting to a network area outside
that used by the Kayenne XL/Kayak HD system, use of an appropriately
configured Ethernet Router is strongly advised. This reduces network
traffic on the switcher network and keeps it isolated. Any Ethernet switches
added specifically for use with the Kayenne XL/Kayak HD system should
be 1000 Mbps capable for the most efficient operation (see
).
Factory Default Network Settings
To integrate Kayenne XL/Kayak HD devices into an existing network, ask
the local network administrator for that network’s subnet mask. Before
changing IP addresses always set the subnet masks of the devices to the
mask of the local network.
Table 10. Ethernet Specifications
Cables
Type
10BaseT, 100BaseT, 1000BaseT compatible.
Category 5 cable, 8 conductor twisted pair.
The system will work at lower ratings with reduced performance.
1000BaseT components are highly recommended.
Connectors
RJ-45 male connector at each end of cable.
Length
100BaseT, 1000BaseT: 328 ft. (100 m) maximum.
10BaseT: 984 ft. (300 m) maximum.
Use additional switches to exceed maximum cable runs.
Switch
Speed
10/100/1000 Mbps
Ports
RJ-45 auto-negotiating 10/100/1000 Mbps; number of ports required
is dependent upon system size. Frame and PCU ports are capable of
1000 Mbps. Using a 1000 Mbps Ethernet switch enhances Image Store
transfer speeds.
Unmanaged
Recommended. Configuration not required, but does not provide
remote monitoring capability.
Managed
May be used. Requires configuration, but offers remote monitoring
capability.
Table 11. Kayenne XL/Kayak HD System Default IP Addresses
Device
IP Address
Video Processor Frame CPU
192.168.0.170
Image Store CPU
192.168.0.171
Control Panel Surface 1A
192.168.0.173
Touch Screen Menu Panel 1
192.168.0.175
Touch Screen Menu Panel 2
192.168.0.176
All Subnet Masks)
255.255.255.0
All Gateways
(except V1.6.5 software Remote Aux panel)
192.168.0.1