Specifications, Kayenne xl package – Grass Valley Kayenne XL Package Installation v.7.0.4 User Manual
Page 28

28
Kayenne XL Package — Installation and Service Manual
Section 1 — Introduction
Specifications
Kayenne XL Package
Table 1. Kayenne XL Mechanical Specifications
Component
Depth (Flat)
Width
Height (Flat) Weight
a
a
All weights approximate.
Rack Units
Control Panels
4.5ME-35, w/o Aux Panel
84.3 mm
(3.32 in.)
1533.7 mm
(60.38 in.)
651.3 mm
(25.6 in.)
n/a
3.5ME-35, w/o Aux Panel
84.3 mm
(3.32 in.)
1533.7 mm
(60.38 in.)
n/a
2.5ME-25, w/o Aux Panel
84.3 mm
(3.32 in.)
1341.7 mm
(52.82 in.)
n/a
1.5ME-15, w/o Aux Panel
84.3 mm
(3.32 in.)
n/a
Local Aux Panel-35
84.3 mm
(3.32 in.)
813.7 mm
n/a
Local Aux Panel-25
84.3 mm
(3.32 in.)
621.7 mm
n/a
Menu Panel
91.7 mm
(3.612 in.)
417.85 mm
(16.45 in.)
270.10 mm
(10.63 in.)
n/a
Panel Control Unit
(PCU)
588.52 mm
(23.17 in.)
482.60 mm
(19 in.)
132.59 mm
(5.22 in.)
3
Kayak HD
4-RU Frame
546.10 mm
(21.5 in.)
482.60 mm
(19 in.)
177.80 mm
(7 in.)
17.69 kg
(39 lbs)
4
Kayak HD
8-RU Frame
522.73 mm
(20.58 in.)
482.60 mm
(19 in.)
441.96 mm
(17.4 in.)
30.39 kg
(67 lbs)
8
Table 2. Environmental
Storage temperature
-20 to 70 deg C (-4 to 158 deg F)
Operating temperature
0 to 40 deg C (68 to 104 deg F)
Relative humidity
0-95% (non-condensing)
Electromagnetic environment
E2 (according to EN55103-1, -2)
Table 3. Network Connections
Type of connection
10/1000 Base T
Protocol
TCP(UDP)/IP, Auto speed detection. Auto crossover cable configuration.
Cable and connectors
CAT5 UTP, RJ45 connectors;
Max. Cable Length
100m / 300ft
1 Frame and up to 4 PCUs connect without of external hub/switch. Each Frame and PCU has internal Ethernet switch.