beautypg.com

Grass Valley Kayenne XL Package Installation v.7.0.4 User Manual

Page 29

background image

Kayenne XL Package — Installation and Service Manual

29

Specifications

Table 4. PCU Interconnects

Control Panel - PCU Connections

Cable and connectors

Custom 7 Pin D style

Number of connections

1 for each Control Panel Stripe, Local Aux Panel, and Satellite Panel

Max. Interconnect Cable Length

15m / 50ft (7.5m / 25ft cable length also available)

Touch Screen Menu Panel - PCU Connection

Cable and connectors

Custom 17 Pin D style

Number of connections

1 for each Touch Screen Menu Panel (2 maximum)

Max. Interconnect Cable Length

15m / 50ft (7.5m / 25ft cable length also available)

Table 5. Power

4-RU Frame

Line voltage

100V-240V AC +/-10% autorange, power factor corrected. Automatic line-
voltage sensing for 120V and 240V sources.

Line frequency

50/60Hz +/- 5%

Power consumption

max. 400W

Leakage current

< 2.5 mA

8-RU Frame

Line voltage

100V-240V AC +/-10% autorange, power factor corrected. Automatic line-
voltage sensing for 120V and 240V sources.

Line frequency

50/60Hz +/- 5%

Power consumption

max. 800W

Leakage current

< 2.5 mA

Panel Control Unit (required for Control Panel and Touch Screen Menu Panel Operation)

Line voltage

100V-240V AC +/-10% autorange, power factor corrected. Automatic line-
voltage sensing for 120V and 240V sources.

Line frequency

50/60Hz +/- 5%

Power consumption

max. 400W

Leakage current

< 2.5 mA

Table 6. Serial Digital Video Inputs

Format

ITU-R656, SMPTE 259M, 270Mbit/s.
SMPTE 292M, 1.5Gbit/s

Number of Inputs

Frame w/ 1 ME Board: 24

Frame w/ 2 ME Boards: 48

Frame w/ 3 ME Boards: 72

Frame w/ 4 ME Boards: 96

Return loss

> 15 db, 5 MHz to 1.5 GHz

Type of Connector

75 ohm BNC (SMPTE 259M)