7. From the rear panel, remove the blank plate that covers the empty codec module slot, as illustrated.
Loosen thumbscrews
1
8. Install the upgrade codec module as illustrated.
Slide in
1
Tighten thumbscrews
2
NOTE: With a firm grip on the metal (EMI) bracket, ensure the board is level and parallel
to the card guides to avoid damage to the components on the edge opposite the rear panel.
CAUTION: Improper handling can damage components on the board. Do not allow the
board to come in contact with the chassis sheet metal during removal or installation. The
components on the edge opposite the rear panel are the most susceptible to damage.
9. Start up the K2 system.
On restart, the K2 sysem rescans hardware and automatically discovers the new codec module.
10. If a message appears, follow the instructions in the message to either restart or shutdown/startup.
This second startup process is necessary so that the K2 system can reconfigure appropriately.
6
K2 Summit/Solo Field Kit Upgrade Instructions
02 February 2012
Upgrade instructions