If you are installing K2-XDP-3G2-FK on a K2 Summit/Solo system, skip ahead and replace the
codec module and power supplies.
•
If you are installing K2-XDP-CPU-FK or K2-XDP-3G1-FK on a K2 Summit system, replace
the CPU carrier module.
Replace CPU carrier module
Do this task if installing K2-XDP-CPU-FK or K2-XDP-3G1-FK on a K2 Summit system.
NOTE: Do not attempt to replace the CPU carrier module on a K2 Solo Media Server.
K2-XDP-CPU-FK and K2-XDP-3G1-FK do not apply to K2 Solo Media Server.
1. Shutdown the K2 Summit system.
2. Disconnect all power cables from the K2 Summit system.
3. Press the power button on the K2 Summit system to drain off power from boards.
4. Remove any cables connected to the CPU carrier module.
5. Replace the current CPU carrier module with the new CPU carrier module.
6. Reconnect cables to the CPU carrier module.
Next, do one of the following:
•
If you are installing K2-XDP-CPU-FK on a K2 Summit system, reconnect power cables, then
skip ahead and replace the CompactFlash boot media.
•
If you are installing or K2-XDP-3G1-FK on a K2 Summit system, replace the codec module.
Related Links
Front bezel assembly removal K2 Summit
on page 35
on page 33
Replace codec module and power supplies
Do this task if installing K2-XDP-3G1-FK or K2-XDP-3G2-FK on a K2 Summit system.
NOTE: Do not attempt to replace the CPU carrier module on a K2 Solo Media Server.
K2-XDP-CPU-FK and K2-XDP-3G1-FK do not apply to K2 Solo Media Server.
Before doing this task, do the following, if not already done:
•
Shutdown the K2 Summit system.
•
Disconnect all power cables from the K2 Summit system.
•
Press the power button on the K2 Summit system to drain off power from boards.
1. Remove any cables connected to the codec modules.