2. For the Control Team and the loopback, select adapter names in the “Device Name” column and
rename them as follows:
a) Select the adapter name.
b) Select
File | Rename
to enter rename mode.
c) Type the name, as specified in the following table:
And rename it as follows:
In the Device Name column, select this adapter name…
Control Team
TEAM : Control Team
3. Do one of the following:
•
If you intend to use SiteConfig for device discovery and IP address configuration, you do not
need to set an IP address for the Control Team at this time. You are done with this procedure.
•
If you are not using SiteConfig, set an IP address for the Control Team at this time. Use
standard Windows procedures.
NOTE: Do not set IP addresses for the two Media Connections.
Next, reorder adapters.
Reorder adapters
Before beginning this task, make sure of the following:
•
Adapters are named correctly according to their PCI bus location
•
The control team is created
•
The team and loopback are named
1. If K2 software is installed, disable the write filter, if it is not already disabled.
2. On the Windows desktop right-click
My Network Places
and select
Properties
.
The Network Connections window opens.
3. Select
Advanced
, then
Advanced Settings…
4. On the
Adapters and Bindings
tab, depending on the K2 system storage, order adapters as follows:
Shared (SAN) storage
Internal or direct-connect storage
Control Team
Loopback
Control Connection #1
Control Team
Control Connection #2
Control Connection #1
Media Connection #1
Control Connection #2
Media Connection #2
Media Connection #1
Loopback
Media Connection #2
1394 Connection
1394 Connection
If controlled by Dyno Production Assistant, refer to Dyno PA documentation for adapter order.
5. Click
OK
to close and accept the changes.
26
K2 Summit/Solo Field Kit Upgrade Instructions
02 February 2012
Upgrade instructions