Create the control team – Grass Valley K2 Summit Client Upgrade Instructions v.8.x Mar.02 2012 User Manual

Page 22

background image

5. Proceed as follows:

If all the names on this system are configured correctly to locations, skip the rest of this
procedure.

If names on this system are not configured correctly to locations, for each adapter name
incorrectly configured, complete the remaining steps of this procedure.

6. Select the name in the Name column.

7. Select

File | Rename

to enter rename mode.

8. Type the name required for the location.

Next, create the Control Team.

Create the Control Team

Before beginning this task, make sure of the following:

Adapters are named

NOTE: Team control ports only. Do not team media ports.

1. In Device Manager, right-click the adapter name that on this system is assigned to location PCI

bus 4, device 0, function 1.

2. Select

Properties

The Properties dialog box opens.

22

K2 Summit/Solo Field Kit Upgrade Instructions

02 February 2012

Upgrade instructions