Triax cable specifications
Note 1
Maximum cable lengths are specified with Draka cables (8 mm and 14 mm). Exact cable
lengths depend on the quality of the cables and connectors used.
Note 2
Video signal rule: cable length is restricted by an attenuation of 24 dB max. at 100 MHz.
Note 3
Teleprompter power rule: maximum cable length is restricted by the conductor plus
screen cable resistance which may not exceed 4
Ω.
1.4
Remote control cables
1.4.1
Standard length cables
Use one of the following RS-422 remote control cables to connect the OCP 400/10 to the
Base Station:
Other signals
Intercom (4-wire or RTS)
RS-422 link to operational control panel
Power supply - ON AIR1 and ON AIR2 indications
Electromagnetic compatibility and
safety devices
Conforms with CE directives (CE marking)
Item
Value
Features used
Cable length (8 mm)
Cable length (14 mm)
Camera video and return signals,
audio signals and control bus
300m (1,000 ft.)
600m (2,000 ft.)
including teleprompter power
100m (330 ft.)
300 m (1,000 ft.)
Cable type:
Product code:
RS-422 Cable (2m)
LDK 8121/02
RS-422 Cable (10m)
LDK 8121/10
RS-422 Cable (25m)