Installation notices
For proper installation the following NEC articles should be noticed:
Regarding communication circuits:
• Installation of equipment (NEC article 800.18).
Regarding radio and television equipment:
• Avoid contact with conductors of other systems (NEC article 810.13);
Provide extensive, separate clearance requirements for indoor and outdoor locations (NEC
article 810.18).
Mains power supply chord
General
A mains power supply chord is not shipped with the device. To connect the device to the
mains the following power supply cord is advised: type H03 VV-F or H03 VVH2-F flexible
wire: 1 mm², 250V / 10A minimum or 16 AWG.
When the device is installed in one of the following countries the power chord must be
compliant to the indicated specifications and regulations below:
Denmark
Supply cord of single-phase equipment having a rated current not exceeding 10A shall be
provided with a plug according to the Heavy Current Regulations section 107-2-D1. Class I
equipment provided with socket-outlets with earth contact or which are intended to be
used in locations where protection against indirect contact is required according to the
wiring rules shall be provided with a plug in accordance with standard sheet DK 2-1a or
DK 2-5a.
Ireland
Apparatus which is fitted with a flexible cable or cord and is designed to be connected to
a mains socket conforming to I.S. 411 by means of that flexible cable or cord and plug,
shall be fitted with a 13A plug in accordance with Statutory Instrument 525:1997 -
National Standards Authority of Ireland (section 28) (13A plugs and Conversion Adaptors
for Domestic Use) Regulations, 1997.
Spain
Supply cords of single-phase equipment having a rated current not exceeding:
•
10A shall be provided with a plug according to UNE 20315:1994
CLASS I EQUIPMENT provided with socket-outlets with earth contacts, or which are
intended to be used in locations where protection against indirect contact is required
according to the wiring rules, shall be provided with a plug in accordance with UNE
20315:1994