Managing interfaces and transceiver modules

Managing combo interfaces

Combo interfaces are logical interfaces. A combo interface comprises one SFP fiber port and one RJ-45
copper port. The two ports cannot work simultaneously because they share the same forwarding
interface. If one port is enabled, the other port is automatically disabled.

Verifying a fiber or copper port

You can use the display interface interface-type interface-number command to identify the SFP fiber port
and RJ-45 copper port.

If the command output includes "Media type is not sure, Port hardware type is No connector", the
port is an SFP fiber port. As shown in the following output, GigabitEthernet 1/1 is an SFP fiber port.

[Sysname] display interface GigabitEthernet 1/1

GigabitEthernet1/1 current state: DOWN

IP Packet Frame Type: PKTFMT_ETHNT_2, Hardware Address: 0000-fc00-7506

Description: GigabitEthernet1/1 Interface

Loopback is not set

Media type is not sure,Port hardware type is No connector

Unknown-speed mode, unknown-duplex mode

Link speed type is autonegotiation, link duplex type is autonegotiation

If the command output includes "Media type is twisted pair, Port hardware type is 1000_BASE_T",
the port is an RJ-45 copper port. As shown in the following output, GigabitEthernet 2/1 is an RJ-45
copper port.

[Sysname] display interface GigabitEthernet 2/1

GigabitEthernet2/1 current state: DOWN ( Administratively )

IP Packet Frame Type: PKTFMT_ETHNT_2, Hardware Address: 0000-fc00-7506

Description: GigabitEthernet2/1 Interface

Loopback is not set

Media type is twisted pair

Port hardware type is 1000_BASE_T

Unknown-speed mode, unknown-duplex mode

Link speed type is autonegotiation, link duplex type is autonegotiation

Configuring combo interfaces

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter interface view.

interface interface-type
interface-number

N/A

3.

Activate the copper or fiber
port of a combo interface. combo enable { copper | fiber }

Required.
By default, the copper port is activated.