beautypg.com

Displaying and maintaining rmon, Table 8 – H3C Technologies H3C WX5500E Series Access Controllers User Manual

Page 81

background image

73

Step Command

Remarks

3.

Create an entry in the
alarm table or private

alarm table.

Create an entry in the alarm table:
rmon alarm entry-number alarm-variable

sampling-interval { absolute | delta }

rising-threshold threshold-value1 event-entry1
falling-threshold threshold-value2 event-entry2

[ owner text ]

Create an entry in the private alarm table:

rmon prialarm entry-number prialarm-formula

prialarm-des sampling-interval { absolute |

changeratio | delta } rising-threshold
threshold-value1 event-entry1
falling-threshold

threshold-value2 event-entry2 entrytype { forever |

cycle cycle-period } [ owner text ]

Use at least one
command.

Table 8 Restrictions on RMON configuration

Entry

Parameters to be compared

Maximum number of

entries

Event

Event description (description string), event type (log, trap,
logtrap or none) and community name (trap-community or

log-trapcommunity)

60

Alarm

Alarm variable (alarm-variable), sampling interval
(sampling-interval), sampling type (absolute or delta), rising

threshold (threshold-value1) and falling threshold
(threshold-value2)

60

Prialarm

Alarm variable formula (alarm-variable), sampling interval
(sampling-interval), sampling type (absolute, changeratio or

delta), rising threshold (threshold-value1) and falling

threshold (threshold-value2)

50

Displaying and maintaining RMON

Task Command

Remarks

Display RMON statistics.

display rmon statistics [ interface-type
interface-number
] [ | { begin | exclude |

include } regular-expression ]

Available in any view.

Display the RMON history
control entry and history

sampling information.

display rmon history [ interface-type
interface-number
] [ | { begin | exclude |

include } regular-expression ]

Available in any view.

Display RMON alarm
configuration.

display rmon alarm [ entry-number ] [ | { begin |
exclude | include } regular-expression ]

Available in any view.

Display RMON private alarm
configuration.

display rmon prialarm [ entry-number ] [ |
{ begin | exclude | include } regular-expression ] Available in any view.

Display RMON event
configuration.

display rmon event [ entry-number ] [ | { begin |
exclude | include } regular-expression ]

Available in any view.