Snmp logging configuration example, Network requirements, Configuration procedure – H3C Technologies H3C WX5500E Series Access Controllers User Manual
Page 74
![background image](https://www.manualsdir.com/files/812984/content/doc074.png)
66
Request binding:
1: 1.3.6.1.2.1.11.29.0
Response binding:
1: Oid=snmpOutTraps.0 Syntax=CNTR32 Value=18
Get finished
# Try to get the device name from the agent. The get attempt fails because the NMS has no access
right to the node.
Send request to 1.1.1.1/161 ...
Protocol version: SNMPv3
Operation: Get
Request binding:
1: 1.3.6.1.2.1.1.5.0
Response binding:
1: Oid=sysName.0 Syntax=noSuchObject Value=NULL
Get finished
# Execute the shutdown or undo shutdown command on an idle interface on the agent. You can
see the interface state change traps on the NMS:
1.1.1.1/3374 V3 Trap = linkdown
SNMP Version = V3
Community = managev3user
Command = Trap
1.1.1.1/3374 V3 Trap = linkup
SNMP Version = V3
Community = managev3user
Command = Trap
SNMP logging configuration example
Network requirements
Configure the SNMP agent (1.1.1.1/24) in
to log the SNMP operations performed by the NMS.
Figure 26 Network diagram
Configuration procedure
This example assumes that you have configured all required SNMP settings for the NMS and the agent
(see "
SNMPv1/SNMPv2c configuration example
").
# Enable displaying log messages on the configuration terminal. (This function is enabled by default.
Skip this step if you are using the default.)