To remove a power module:

1.

Wear an ESD-preventive wrist strap and make sure it makes good skin contact and is well
grounded.

2.

Remove the power cord from the power module. When removing the DC power cord, squeeze the
tabs on the power cord connector with your thumb and forefinger and then pull the connector out,

as shown in

Figure 31

.

3.

Hold the handle on the power module with one hand, pivot the latch on the power module with
your thumb, and pull the power module part way out of the slot. Then supporting the power module

bottom with one hand, slowly pull the power module out with the other hand, as shown in

Figure

32

and

Figure 33

.

Put the removed power module in an antistatic bag.
Install a filler panel if no power module is to be installed.

Figure 31 Removing the DC power cord

(1) Press the tabs on the power cord connector with your thumb
and forefinger

(2) Pull the power cord connector out

Figure 32 Removing the power module (S5830-52SC)

(1) Pivot the latch to the right with your thumb

(2) Pull the power module out